Product Overview
The JH2810 Three-Phase Winding Resistance Tester is designed to cut transformer DC resistance testing time. It delivers high output current in a compact, lightweight body, making it easy to carry to any job site. Controlled by a microprocessor, it automatically handles self-testing, data processing, and safe auto-discharge. This unit provides fast and stable readings for distribution transformers, power transformers, reactors, and generators. It is also ideal for rapid resistance testing of switches, copper bars, contactors, and cable accessories.
Key Features & Benefits
High Output, Lightweight Design
Delivers powerful output current in a compact body for easy field transport.
5 Adjustable Current Levels
Ranges from 5mA to 10A, allowing you to match the exact test requirements for different winding sizes.
Built-in Lithium Battery
High-capacity battery ensures all-day operation on-site without needing an external power outlet.
Wide Measurement Range (0–20kΩ)
Perfect for testing transformers, motors, switches, relay contacts, and metal wires.
Sunlight-Readable Display
Simple, intuitive menus with a bright TFT LCD screen for clear visibility in outdoor environments.
Advanced Protection Circuits
Built-in auto-discharge and back EMF protection prevent arc damage and ensure highly stable unbalance test data, even if the test line is accidentally disconnected.
Product Parameter
| Specification | Details |
| Model | JH2810 |
| Power Supply | Built-in 12.6V/5.2Ah Lithium Battery (with dedicated power adapter) |
| Output Current | 5mA, 100mA, 300mA, 1A, 10A (Auto/Manual Range Selection) |
| Measurement Range | 10A Range: 0 ~ 0.1Ω 1A Range: 0.03 ~ 6Ω 300mA Range: 0.1 ~ 20Ω 100mA Range: 0.3 ~ 60Ω 5mA Range: 30 ~ 20kΩ |
| Accuracy | ≤ 1.000kΩ: ±(0.2% RD + 0.05% FS) > 1.000kΩ: ±(0.2% RD + 0.01% FS) |
| Minimum Resolution | 1μΩ |
| Display | TFT LCD Screen |
| Operating Temperature | -10°C to 40°C |
| Operating Humidity | ≤ 80% RH, non-condensing |
| Storage Conditions | -20°C to 50°C, ≤ 95% RH, non-condensing |
| Dimensions (L×W×H) | 320 × 270 × 140 mm |
Standard Accessories
- 1 × Main Unit (with built-in battery)
- 1 × Durable Carrying Case
- 1 × Set of Dedicated Test Leads
- 1 × USB Cable
- 1 × Standard Resistor
- 1 × Instruction Manual
- 1 × Certificate of Conformity & Warranty Card

Safety Precautions
- For indoor and outdoor use only. Avoid operating in rain, corrosive gas, dusty, or excessively hot environments.
- Read the instruction manual thoroughly before first use.
- Only qualified personnel with basic electrical safety knowledge should operate this instrument.
- This is a high-precision device. Avoid dropping or subjecting it to strong vibrations.
- Repairs, maintenance, and calibration must be performed by authorized service personnel only.
- After each test, wait for the auto-discharge alarm to stop before turning off power or removing test leads.
- When testing on-load tap changers, always wait for discharge to complete before switching taps.
- Never disconnect test clips or power lines during testing-especially during three-phase unbalance tests-to prevent data errors and potential hazards.
Why Choose JiuHua JingCe?
13+ Years of Manufacturing Expertise
Established in 2013 in Wuhan Optics Valley, we are a direct manufacturer, not a trader.
One-Stop Solutions
From Insulation to Transformer Testers, we serve power, railway, and petrochemical industries.


Strict Quality Control
Every unit undergoes rigorous testing to ensure high precision and durability.
Trusted Globally
Our equipment meets professional standards across energy and heavy industries.
FAQ
Q: Can this instrument test the three-phase unbalance rate of transformers?
A: Yes. It features a dedicated three-phase test mode that automatically calculates and displays the unbalance rate on the screen immediately after the winding resistance test is completed-no manual calculation required.
Q: What settings are required before starting a three-phase unbalance test?
A: You need to configure the connection group, tap position, test side (HV/LV), test current, and ambient temperature. For YN-connected transformers, the system defaults to neutral point testing (A-0, B-0, C-0), but non-neutral point testing can also be selected if needed.
Q: What formula does the instrument use to calculate the unbalance rate?
A: The instrument automatically applies the industry-standard formula:
Unbalance Rate = (R_max - R_min) / R_average
The calculation is performed instantly by the device once the three-phase data is acquired.
Hot Tags: winding resistance tester three phase unbalance test, China winding resistance tester three phase unbalance test manufacturers, factory, dc resistance test, Transformer dc resistance tester, DC Winding Resistance Tester 20A, transformer voltage ratio tester, transformer dc winding resistance meter, 3 phase winding resistance