Winding Resistance Tester Three Phase Unbalance Test

Send Inquiry
Winding Resistance Tester Three Phase Unbalance Test
Details
⚡ Test 3 Phases at Once
⏱️ Cuts Testing Time by 66%
🛡️ Safe Auto-Discharge Alarm
📊 Auto Unbalance Calculation
🔋 High 20A Fast Output
💾 Stores 500+ Test Records
🌡️ Built-in Temp Compensation
🏗️ Rugged Field Design
✅ 0.2% High Accuracy
Category
Transformer Winding Resistance Tester
Share to
Description
Three-Phase Winding Resistance Tester

Product Overview

 

The JH2810 Three-Phase Winding Resistance Tester is designed to cut transformer DC resistance testing time. It delivers high output current in a compact, lightweight body, making it easy to carry to any job site. Controlled by a microprocessor, it automatically handles self-testing, data processing, and safe auto-discharge. This unit provides fast and stable readings for distribution transformers, power transformers, reactors, and generators. It is also ideal for rapid resistance testing of switches, copper bars, contactors, and cable accessories.

Key Features & Benefits
 

High Output, Lightweight Design

Delivers powerful output current in a compact body for easy field transport.

5 Adjustable Current Levels

Ranges from 5mA to 10A, allowing you to match the exact test requirements for different winding sizes.

Built-in Lithium Battery

High-capacity battery ensures all-day operation on-site without needing an external power outlet.

Wide Measurement Range (0–20kΩ)

Perfect for testing transformers, motors, switches, relay contacts, and metal wires.

Sunlight-Readable Display

Simple, intuitive menus with a bright TFT LCD screen for clear visibility in outdoor environments.

Advanced Protection Circuits

Built-in auto-discharge and back EMF protection prevent arc damage and ensure highly stable unbalance test data, even if the test line is accidentally disconnected.

 

Product Parameter

 

SpecificationDetails
ModelJH2810
Power SupplyBuilt-in 12.6V/5.2Ah Lithium Battery (with dedicated power adapter)
Output Current5mA, 100mA, 300mA, 1A, 10A (Auto/Manual Range Selection)
Measurement Range10A Range: 0 ~ 0.1Ω 
1A Range: 0.03 ~ 6Ω 
300mA Range: 0.1 ~ 20Ω 
100mA Range: 0.3 ~ 60Ω 
5mA Range: 30 ~ 20kΩ
Accuracy≤ 1.000kΩ: ±(0.2% RD + 0.05% FS) 
> 1.000kΩ: ±(0.2% RD + 0.01% FS)
Minimum Resolution1μΩ
DisplayTFT LCD Screen
Operating Temperature-10°C to 40°C
Operating Humidity≤ 80% RH, non-condensing
Storage Conditions-20°C to 50°C, ≤ 95% RH, non-condensing
Dimensions (L×W×H)320 × 270 × 140 mm

 

 

Standard Accessories

 
  • 1 × Main Unit (with built-in battery)
  • 1 × Durable Carrying Case
  • 1 × Set of Dedicated Test Leads
  • 1 × USB Cable
  • 1 × Standard Resistor
  • 1 × Instruction Manual
  • 1 × Certificate of Conformity & Warranty Card
Standard Accessories of Three-Phase Winding Resistance Tester

 

 

Safety Precautions

  • For indoor and outdoor use only. Avoid operating in rain, corrosive gas, dusty, or excessively hot environments.
  • Read the instruction manual thoroughly before first use.
  • Only qualified personnel with basic electrical safety knowledge should operate this instrument.
  • This is a high-precision device. Avoid dropping or subjecting it to strong vibrations.
  • Repairs, maintenance, and calibration must be performed by authorized service personnel only.
  • After each test, wait for the auto-discharge alarm to stop before turning off power or removing test leads.
  • When testing on-load tap changers, always wait for discharge to complete before switching taps.
  • Never disconnect test clips or power lines during testing-especially during three-phase unbalance tests-to prevent data errors and potential hazards.
Why Choose JiuHua JingCe?

13+ Years of Manufacturing Expertise

Established in 2013 in Wuhan Optics Valley, we are a direct manufacturer, not a trader.

One-Stop Solutions

From Insulation to Transformer Testers, we serve power, railway, and petrochemical industries.

Our Company
our product display

Strict Quality Control

Every unit undergoes rigorous testing to ensure high precision and durability.

Trusted Globally

Our equipment meets professional standards across energy and heavy industries.

 

FAQ

 

Q: Can this instrument test the three-phase unbalance rate of transformers?

A: Yes. It features a dedicated three-phase test mode that automatically calculates and displays the unbalance rate on the screen immediately after the winding resistance test is completed-no manual calculation required.

Q: What settings are required before starting a three-phase unbalance test?

A: You need to configure the connection group, tap position, test side (HV/LV), test current, and ambient temperature. For YN-connected transformers, the system defaults to neutral point testing (A-0, B-0, C-0), but non-neutral point testing can also be selected if needed.

Q: What formula does the instrument use to calculate the unbalance rate?

A: The instrument automatically applies the industry-standard formula:
Unbalance Rate = (R_max - R_min) / R_average
The calculation is performed instantly by the device once the three-phase data is acquired.

 

 

Hot Tags: winding resistance tester three phase unbalance test, China winding resistance tester three phase unbalance test manufacturers, factory, dc resistance test, Transformer dc resistance tester, DC Winding Resistance Tester 20A, transformer voltage ratio tester, transformer dc winding resistance meter, 3 phase winding resistance

Send Inquiry